The net free area is always less than the actual area.
Attic ventilation net free area.
Let owens corning roofing help you calculate exactly how much ventilation you will need for a healthy and balanced attic with our 4 step ventilation calculator.
Besides the rated air ventilation area described by various vent product manufacturers other roof and vent opening details can significantly affect the actual airflow and level of under roof ventilation at a building.
This calculates the 2015 international residential building code minimum irc section r806 roof ventilation 1 which states that 1 square foot of net free area for every 150 square feet of attic floor space with the attic defined as length x width floor of the attic.
O hagin standard line of attic vents is available for contractor painting in 26 gauge g90 mill finish galvanized steel 0 032 aluminum 16 oz.
Attic square footage 2 square inches of exhaust and square inches of intake net free area nfa needed.
Eave vent gable vent roof jack soffit vent screen factor sf mesh sf w o louvers sf w louvers 1 4 or 1 2 1 0 2 0 1 8 1 25 2 25 1 16 2 0 2 0 nfa for common attic vents attic vents nfa.
The total net free area of the intake and exhaust must be balanced.
A normal metal pot vent produces only 50 squares inches of free net area.
If you do not have upper vents within 3 ft of the ridge then use 1 150.
Should you need to add more air intake ventilation to your attic simply determine the number of vents needed from the table based on your net free area requirements.
Two square feet equals 288 square inches.
The passive vent net free area table gives the net free area ventilation for some common roof and gable passive vents.
Comments opinion about statements of net free ventilation area of various roof venting products.
Calculate or enter the square footage of the attic or area to be vented.
This attic vent provides maximum airflow 72 square inches of net free ventilation area nfva without detracting from the aesthetics of the roof design.
Check with your building official for current code and a copy of the section regarding roof ventilation.
So for a 2400 sf attic space covered by roof you only need 8 sf of net free vent area to comply with the building code.
The calculations before indicated that we needed 2 square feet of ridge or upper roof ventilation.
So we would need at least six metal vents in addition to the lower soffit ventilation to meet minimum ventilation requirements.
Nfa is the unobstructed area through which air can pass through a vent usually measured in square inches.
Helpful hint for the 1 150 attic ventilation requirement simply double the amount of exhaust and intake calculated.