Our passive roof vents are ul certified and rated to withstand wind pressure in excess of 200 mph.
Attic ventilation requirements calculator.
All lomanco attic ventilation product requirements are based on the minimum standard 1 300 rule as set forth by the international building code ibc and the international residential code irc.
Use this calculator to help determine the proper amount of attic ventilation based on u s.
Let owens corning roofing help you calculate exactly how much ventilation you will need for a healthy and balanced attic with our 4 step ventilation calculator.
Length x width of attic in feet 150 total sq.
Federal housing authority recommends a minimum of at least 1 square foot of attic ventilation evenly split between intake and exhaust for every 300 square feet of attic floor space.
In order to find the right calculator divide the attic floor.
Width or area.
Calculating attic ventilation requirements.
According to their requirements you should have 1 square foot of attic ventilation per 300 sq ft of attic floor space.
Calculate the total vent area needed.
Of total vent space needed.
The following are the requirements taken directly from the irc.
Divide the square footage item 1 by 300.
If your roof is 1200 sq ft soffit floor space you will need 4 sq feet of roof ventilation.
Home attic vent calculator for years we have been working with architects and specifiers to ensure affordable roof ventilation that upholds building code standards.
The majority of the requirements related to attic ventilation have not changed much from the previous editions.
Select ventilation product flex roll ridge vent multi roll multi purpose vent rigid roll ridge.
Gaf attic ventilation calculator.
Vent calculator design your balanced ventilation system.
The two square feet is divided equally between the intake and the exhaust one square foot for each.
Roof ventilation calculator enter your attic area or length and width to determine your ventilation needs.
Hence you would need two square feet 600 300 of attic ventilation.
The ventilation amount and opening size requirements can be found in section 806 roof ventilation of chapter 8 roof ceiling construction.
Result of item 1 300.
Multiply the length of the attic times the width in feet to find the attic area then divide by 150 to find the total square feet of vent space needed.
Proper attic ventilation consists of a balance between air intake at your eaves soffits or fascias and air exhaust at or near your roof ridge.
Proper attic ventilation consists of a balance between air intake at your eaves soffits or fascias and air exhaust at or near your roof ridge.
Ft divided by 150 equals 10 sq.
There should also be a 50 50 balance of attic venting and roof venting.